Flex and Fixed GPIO

GPIO

LUNA-F has 24 flex inputs/outputs which can be configured in all possible ways. On the other hand, LUNA-U has fixed 12 GPIO input and 12 GPIO output ports. LUNA series GPIO ports are both edge and configurable threshold level triggered. Input possibilities are active low/high, rising/falling edge and analog input 0-33V. Output is open drain. 

The internal 24V is capable of delivering a maximum current of 1 Amp.

Note: The video content may be changed or updated in time.

The first screenshot below shows the GPIO Overview menu of the LUNA-F. It can be seen that GPIO ports 1 and 2 are already configured as GPO. You can switch between GPI and GPO by clicking on the greyed-out x label.

The second screenshot shows the fixed 12 GPIO input and 12 GPIO output ports of the LUNA-U. To configure GPIO, click on the gear icon next to the label.

GPIO Input

Parameter Name

Parameter Range

Parameter Definition

Full Name

Not Available

Full name is used on the GPIO label and the drop-down selection lists for triggers

Short Name

Not Available

Input Setting

Not Available

Sets the trigger voltage range and provides a visual representation of both trigger and result

Set 1

0 - 28 V

Sets the lower voltage limit for the trigger

Set 0

0 - 28 V

Sets the higher voltage limit for the trigger

-wiring diagrams-

GPIO Output

Parameter Name

Parameter Range

Parameter Definition

Full Name

Not Available

Full name is used on the GPIO label and the drop-down selection lists for contacts

Short Name

Type

Selection

A list of GPO behaviors that can be selected

Hold

Selection

Holds the contact as long as the trigger is available (e.g. keep the exit light on when there is a fire alarm trigger)

Pulse

Selection

Holds the contact momentary, for a defined time when the trigger is available. The "On Time" slider defines the pulse's hold time.

On Time

10 - 30000 ms

The "On Time" slider defines the pulse's hold time.

Vibration

Selection

The vibrator type sets a series of pulses where the on-time and off-time parameters set how frequently the pulses should be generated. 

On Time

10 - 30000 ms

The "On Time" slider defines the vibrator's on-time lengths.

Off Time

10 - 30000 ms

The "Off Time" slider defines the pulse's off-time lengths.

Invert Trigger

True/False

Inverts the result/output of the trigger.

Simulation

Not Available

Provides a visual representation of the trigger and result.

GPIO Status/Trigger

1/0

Sets the trigger status for the GPO contact. You can activate the GPO contact when there is a trigger or in absence of a trigger.

 

 

Top