Flex and Fixed GPIO
GPIOLUNA-F has 24 flex inputs/outputs which can be configured in all possible ways. On the other hand, LUNA-U has fixed 12 GPIO input and 12 GPIO output ports. LUNA series GPIO ports are both edge and configurable threshold level triggered. Input possibilities are active low/high, rising/falling edge and analog input 0-33V. Output is open drain.
The internal 24V is capable of delivering a maximum current of 1 Amp.
Note: The video content may be changed or updated in time.
The first screenshot below shows the GPIO Overview menu of the LUNA-F. It can be seen that GPIO ports 1 and 2 are already configured as GPO. You can switch between GPI and GPO by clicking on the greyed-out x label.
The second screenshot shows the fixed 12 GPIO input and 12 GPIO output ports of the LUNA-U. To configure GPIO, click on the gear icon next to the label.
GPIO Input
Parameter Name | Parameter Range | Parameter Definition |
Full Name | Not Available | Full name is used on the GPIO label and the drop-down selection lists for triggers |
Short Name | Not Available | |
Input Setting | Not Available | Sets the trigger voltage range and provides a visual representation of both trigger and result |
Set 1 | 0 - 28 V | Sets the lower voltage limit for the trigger |
Set 0 | 0 - 28 V | Sets the higher voltage limit for the trigger |
-wiring diagrams-
GPIO Output
Parameter Name | Parameter Range | Parameter Definition |
Full Name | Not Available | Full name is used on the GPIO label and the drop-down selection lists for contacts |
Short Name | ||
Type | Selection | A list of GPO behaviors that can be selected |
Hold | Selection | Holds the contact as long as the trigger is available (e.g. keep the exit light on when there is a fire alarm trigger) |
Pulse | Selection | Holds the contact momentary, for a defined time when the trigger is available. The "On Time" slider defines the pulse's hold time. |
On Time | 10 - 30000 ms | The "On Time" slider defines the pulse's hold time. |
Vibration | Selection | The vibrator type sets a series of pulses where the on-time and off-time parameters set how frequently the pulses should be generated. |
On Time | 10 - 30000 ms | The "On Time" slider defines the vibrator's on-time lengths. |
Off Time | 10 - 30000 ms | The "Off Time" slider defines the pulse's off-time lengths. |
Invert Trigger | True/False | Inverts the result/output of the trigger. |
Simulation | Not Available | Provides a visual representation of the trigger and result. |
GPIO Status/Trigger | 1/0 | Sets the trigger status for the GPO contact. You can activate the GPO contact when there is a trigger or in absence of a trigger. |