Device settings

Device
Device Name

Parameter Name

Parameter Range

Parameter Definition

Full Name

Not Available

Full name is used on the drop-down selection lists and in the Dante Controller for Dante channels.

 

Full name is also used as device/Bluetooth name on the NWP series.

 

Short Name

Not Available

Short is used on the overview screen channel labels
Version

Parameter Name

Parameter Range

Parameter Definition

Firmware Version

Not Available

Indicates the installed firmware version.

Build Number

Not Available

Indicates the build number of the installed firmware version.

Update Firmware

Not Available

The available firmware version can be installed here. The latest and previous versions are both available. Using the latest AUDAC Touch version and firmware is highly recommended to get the most out of your Atellio family devices.

When a new firmware version is available, the button will be highlighted in orange.

Target Devices Settings

Parameter Name

Parameter Range

Parameter Definition

Target Devices

Not Available

Up to 20 devices can be set as target devices for paging and voice file announcements.

Target Device

Selection

Selecting any LUNA series in the device inventory from the drop-down list is possible.

Paging Input

Selection

Selected device channels should be subscribed to the dedicated NPM200 Dante channels, Dante Paging Out for paging and Dante Voice File Out for voice files.

Voice File Input

Selection

Selected device channels should be subscribed to the dedicated NPM200 Dante channels, Dante Paging Out for paging and Dante Voice File Out for voice files.
Physical Button Settings

Parameter Name

Parameter Range

Parameter Definition

Physical Button Function

Selection

Provides two function options for the physical button of NPM200.

Push to start, release to stop

Not Available

Push the physical button to start the announcement and the microphone will unmute, you can release the physical button once the announcement is done and the microphone will mute.
Push once to start, again to stop

Not Available

Push the physical button to start the announcement and the microphone will unmute, you can push again to the physical button once the announcement is done and the microphone will mute.
Network Settings

Parameter Name

Parameter Range

Parameter Definition

DHCP

Enable/Disable

Switch between dynamic or static IP

MAC

Not Available

MAC address of the device

IP

Not Available

The IP address of the device can be set here when DHCP is disabled (e.g. 192.168.20.170)

Mask

Not Available

The subnet mask can be set here (e.g. 255.255.255.0)

Gateway

Not Available

The gateway IP address can be set here for the devices that act as the bridge for the network traffic like the network switch (e.g. 192.168.20.1)

DNS1/DNS2

Not Available

The primary and secondary/alternative DNS addresses can be set here (e.g. 1.1.1.1)
Device Address

Parameter Name

Parameter Range

Parameter Definition

Index

Enable/Disable

You can set a unique number to the device in a scenario where you have more than one of the same device.

Pin Code Setting 

A 4-digit PIN code prevents unauthorised persons from accessing the update and factory reset menu. This feature is available with firmware version 1.2.0. The pin code is 0000 by default.

The PIN code can be configured on Audac Touch, under the "Device" menu. When a 4-digit PIN code is entered the “Submit” button is highlighted in green. Clicking on the button sets the PIN code.

On the NPM200, clicking the gear icon opens the PIN code panel. The PIN code automatically unlocks if the typed 4-digit PIN code is correct. If the typed PIN code is incorrect, the “Wrong PIN code, try again!” message is displayed on top.

Parameter Name

Parameter Range

Parameter Definition

Clear

Not Available

Clears the typed PIN code and displays the message "Please enter PIN code" on top

Back

Not Available

Returns to dashboard. The PIN code panel stays active if you do not press the ‘Back’ button.

Top